What is the installation method of the terminal tension tester?

What is the installation method of the terminal tension tester?
If you do not know the user of the terminal tension tester installation method, you can explore the installation method of the terminal tension tester along with Xiaobian.
1. Installation method of the base: This instrument can be installed on the table to make the instrument more stable. When installing, please ensure that the work surface is level, so that the test gets accurate values. Please refer to (length × width: 430mm × 80mm, 4 M4 threaded holes) for installation.
2. Installation method of push-pull force meter: A. Use M4 wrench to loosen four M4×16 hexagon socket head cap screws on the dynamometer mounting plate and remove the dynamometer mounting plate;
B. Install push-pull timing of the HF series (digital push-pull gauge). Use the M4 Allen wrench to insert the four M4×10 Allen screws in the accessory bag through the 90×40 holes on the dynamometer mounting plate. Screw into the threaded holes of the four M4 dynamometers and install the dynamometer on the dynamometer mounting plate; or use a Phillips screwdriver to insert four fine × 10 Phillips pan head screws in the accessory bag through the force measurement Inside the meter, mount the dynamometer to the dynamometer mounting plate. The 145 x 30 holes on the mounting plate are screwed into 4 fine threaded holes of the dynamometer;
1) Install the push-pull timing of the NK series (pointer push-pull gauge). Use a Phillips screwdriver to remove the four M×10 screws on the back cover of the push-pull gauge. The slot screw passes through the 145 x 30 mounting holes on the dynamometer mounting plate and is screwed into the four precision threaded holes on the dynamometer rear cover (remove the threaded holes of the fine x 10 screws);
2) After installing the push-pull meter, use the M4 Allen wrench to reinstall the dynamometer mounting plate on the rack.
Terminal Tension Tester Left Fixture Installation Method: Use an M4 Allen key to screw 4 M4×10 Allen screws in the accessory bag through the 4 holes on the left fixture mounting plate to the machine base plate 4 M4 In the threaded hole, install the left fixture to the base plate of the machine.
Terminal Rally Tester Right Fixture Installation Method: First use the M6 ​​nut in the attachment to rotate the dynamometer's measuring rod, then rotate the right grip to the dynamometer's measuring rod, adjust the M6 ​​nut to the right gripper Can be firmly connected one after another;
Terminal Force Tester Picture
Terminal tension tester
Terminal tension tester