LockHub intelligent door lock management system operation method with registration code instructions

LockHub smart door lock management software how to operate? How does LockHub Smart Lock manage door locks? How to use the LockHub registration code? LockHub is a powerful intelligent lock management system software. The latest version can realize smart locks for mobile phones and computers, and realize the functions of issuing cards, reading cards, and logging out. It is a relatively common intelligent door lock management system, and the user needs to input. Registration code activation software for use and other operations. wBO smart lock China

2017-05-17_091651.jpg wBO smart lock China

LockHub intelligent door lock management system setting operation steps

After the door lock is installed, you must use the installation card to set the door lock system before putting it into use. The setting process is as follows: wBO smart lock China

In the [Maintenance] menu, find [Door Lock Room Number Settings] and create a mounting card. Use the mounting card to set the door lock number on the door lock. Blue light, two rings, indicating successful installation. wBO smart lock China

Note: The installation card cannot set the door lock of the existing system information. If you want to reset the door lock, use the card to clear the door lock information. The blue light is on and a beep sounds, indicating that there is information in the lock. If you want to reset it, please clear the card first. wBO smart lock China

Install the card with its own clock. If the manufacturing time and the setup time differ by more than five minutes, please check the time with the clock card after setting the lock information. wBO smart lock China

LockHub smart door lock management system card management use method

1. Open function card: wBO smart lock China

Master Control Opening Card: All door locks can be unlocked, even if unlocked. Generally held by the general manager of the hotel, room manager and other management personnel, the total card has a report loss function. If any loss occurs, the loss report should be used to replace the card and use it to open all the door locks, so that the original card opens the door. The function will be invalid. If you need to restore the door opening function of the card that has been reported to be lost, you only need to re-do the total card in the system. wBO smart lock China

Loudong opening card: open all the doors of a building, can not open anti-lock. Such as: *** big hotel \*** building. Usually held by room managers. wBO smart lock China

Floor opening card: Open all doors of a certain floor in a certain area. Such as: *** big hotel \*** building \*** floor. wBO smart lock China

Emergency opening card: All doors can be opened, including unlocked. After use, the door lock state is always on. This can be terminated by opening the door with a valid opening card. This card is generally not used, only use this card in special circumstances. wBO smart lock China

Area opening card: You can open the door lock of the specified area. This card does not affect the normal function of other types of opening cards. wBO smart lock China

Password opening card: used to open the corresponding lock password. wBO smart lock China

Channel opening card: open designated door, with alternate door opening function (touch once, then touch once again), generally used for meeting rooms or other special occasions. wBO smart lock China

2017-05-17_091651_72x72.jpg wBO smart lock China

2, set the function card wBO smart lock China

Clock card: used to correct and set the clock inside each room door lock. The card is valid at that time. wBO smart lock China

Clear card: Clear the door lock information and return the door lock to the initial state. The card is valid on the same day. wBO smart lock China

Area setting card: Set the area number for the door lock in the specified area, and set the area number of the door lock. If you want the area area to open the door to open the door, you need to issue the area opening card corresponding to the area number. wBO smart lock China

Reset card: reset the characteristic information in the door lock. If the door opening card is issued after the computer's clock is chaotic, it may cause the door to fail. In this case, the reset card and the clock card can be reset to restore the normal door opening function. wBO smart lock China

Blocked cards: used to close unused rooms. During the blockade of the room, all door opening cards, except emergency cards, cannot be opened. wBO smart lock China

Unlock the card: The door used to unlock the blocked card. wBO smart lock China

Password setting card: used to set the password to the door lock. If the password opening card needs to open the door successfully, you must find the corresponding password in the door lock to complete the door opening action. This password is the password set by the password setting card. wBO smart lock China

Password clearing card: used to clear the corresponding password in the door lock. This function is mainly used to open the door to unlock the password. After the password is cleared, if you need to restore the password to open the door and open the door, you can reset the password and re-open the password. You can. wBO smart lock China

The current version of the door lock system, a door lock can store 16 groups of passwords at the same time, use the password to open the door to complete the cross-open door lock function. wBO smart lock China

Emergency code setting card: After an emergency door opening card is lost and lost, it can use this card to carry out card or card insertion on the door lock, then the old emergency door opening card opening function will be invalid! wBO Smart Lock China

Check-out time setting card: Card used to limit check-out time. This card only sets a uniform check-out time for the hotel. Generally, it cannot be used to terminate the door opening function of the guest card for some reason. After this card is set, it is generally a fixed function. wBO smart lock China

Room number display card: The door lock display module is used for room number information display. wBO smart lock China

Elevator setup card: Use the elevator setup card to set the elevator number. wBO smart lock China

Note: The actual floor number corresponding to the floor name in the system must be set for the actual number of the actual floor where the elevator is located. wBO Smart Lock China

Display setting card: This card is a function card for setting display information in the door lock display module. Note: Each card can only write 4 Chinese characters or 8 letters at a time, so the maximum display content can only be 64 Chinese characters or 128 letters. wBO smart lock China

LockHub smart lock system registration code activation instructions

In the password, enter: 12345, then press the [Login] button to enter the system and begin the system's first use of the door lock authorization registration operation. When registering, select the type of door lock, enter the authorization code, and place the authorization card on the reader. If no authorization code or authorization code has expired, you can select the later registration option to obtain the correct and valid registration code through the information code. wBO smart lock China

At this time, the software supplier of the door lock information code will obtain the correct and valid door lock authorization code and enter the system after being properly authorized. After entering the system, the main function interface of the system will be displayed. wBO smart lock China

Users can set new room number data in menu [System]->[System Parameter]. After the first time the system is running, it is necessary to confirm the new room number data, confirm the new operator information and the corresponding permission functions. After all the basic parameters are set, the business operations can be started. wBO smart lock China

2017-05-17_091748.jpg wBO smart lock China

LockHub smart lock management system instructions

The smart lock management system is mainly used for issuing and returning cards, and its functions are relatively simple. There are no functions such as cash register management required by the hotel front desk. wBO smart lock China

The initial password of the intelligent door lock management software is: 12345. It is recommended to modify it immediately after login so that the password is not leaked. wBO smart lock China

This software is supported by both the T5557 and M1 cards, mainly to see if the card issuing machine is M1 or T5557. You need to purchase a door card to perform operations such as registering and issuing a card. wBO smart lock China

How to identify the card type? Flashlight from the back of the card, and then see the light through the coil, the square is the M1 card, the round is the T5557 card, but even if the card type is the same, or need to lock the manufacturer to encrypt, in order to issue the card in the system. wBO smart lock China

1. If the issued card is lost, it should report the issuance of a card of the same type, and use this card to lock all the doors it can open to open the door and report the previous valid card. wBO smart lock China

2. Please backup your data frequently during use. After the database is damaged, you can use this backup to restore. wBO smart lock China

With smart lock management software complete graphic version of the manual download link: https://pan.baidu.com/s/1skIjonj password: iye7. wBO smart lock China

The above information is published by Smart Lock China Network Xiaobian. For more information, please refer to this column! wBO smart lock China

Sectional Garage Door

Dongguan HengTaichang Doors Co, Ltd. , https://www.dghtcdoors.com