High temperature pump design should pay attention to the problem

1. According to the actual use of conditions to determine the steam inlet and outlet pressure drop. Steam trap inlet pressure is due to fluctuations in steam pressure or temperature regulating valve throttling, steam trap inlet minimum working pressure; steam trap outlet pressure refers to the steam trap may form the highest back pressure When discharged into the atmosphere, the actual pressure difference is determined by the steam trap inlet pressure. 2. According to the amount of condensate generated by the steam heating equipment during normal operation, multiply by the correction factor k and select it according to the displacement of steam traps. 3. The amount of condensate can be calculated as follows: (1) The amount of condensate generated during pipeline operation Q = q0L (1-Z /%) (kg / h), where Q is the volume of condensate (kg / h) : Condensate generated by the light pipe Pressure reducing valve (kg / h) L: distance between hydrophobic points (m) Z: thermal insulation efficiency (%) (2) Condensation water generated during steam heating operation Q = VrC △ T / Ht, where Q is the amount of condensate (kg / h) V is the volume of the heated object (m3) r is the density of the heated object Solenoid valve C is the specific heat of the fluid (kcal / kg .OC) △ T: liquid temperature rise (OC) H: latent heat of steam (kcal / kg) t: heating time 4. The values ​​of the selected correction coefficient K for common operating conditions are recommended in Table 1 below. 5. Various types of steam traps structure and principle is different, different performance fluids, when used according to different occasions, choose different steam traps.

Swing Door

1.with 3000 square meter factory about 35 workshop workers and 25 office workers.

2.More than 20 sets of advanced machines with more than ten years domestic trade experience and international trade experience.

3.Manufacture and supply good quality automatic doors

4.With ISO 9001 Certification and many others certifications

5. Excellent DC brushless motor , high wear-resistant qualities wheels and reasonable structure design makes it more stable, quiet, longer life

6.Our Service system is perfect


Controller Dimensions : 85×124×600mm

Weight :12 kg

Maximun leaf weight :150 kg

Open range : 70°~115°

Closing speed : 10~43 cm/s

Door hold time :0.5~10 seconds

Main Power :AC 220V~250V,50~60 Hz

Maximum current :1A

Maximun motor power:55W

Wait Power :14W

Fuse :Minimum 3.5 ASlow

Operating Temperature : -30℃ ~+50℃

Swing Door,Exterior Swing Door,Aluminium Out Swing Door,Refrigerated Swing Door

Shenzhen Hongfa Automatic Door Co., Ltd. , https://www.hffreezerdoor.com